Extension/Compensating Conductor

Compensating and extension grades of wire are supplied in the bright-annealed condition. Extension and compensating cable provide convenient, economic solution.

Extension grade wire is a less expensive, lower grade wire. Extension grade Conductors have a working temperature range from 0°C to 200°C.

Compensating grade wire is a type of thermocouple wire that uses a different composition of alloys. Compensating grade wire is made from cheaper alloys than extension cable. Compensating grade Conductors have a working temperature range from 0°C to 100°C.

In case of KCA temperature range is up to 0°C to 150°C.

  • Type

    KX, TX, JX, NX, EX, KCA, KCB, RCB/SCB

  • Diameter

    0.16 mm to 3.0 mm Diameter

  • Standard

    ANSI MC 96.1, other standard as per customer requirement

Type Conductor (*)
Chemical Composition %
Conductor (-)
Chemical Composition %
American Standard
ASTM E230/ANSI MC95.2
European Standard IEC 584
Ni Cr Fe Cu Others Cu Ni Others T/c Range Class 1
(0.4%)
Class 2
(0.75%)
T/c Range Class 1
(0.4%)
Class 2
(0.75%)
KX 90 10 Si+ 94 Si+ Mn+
Others
0°C to 200°C ±1.1°C ±2.2°C -25°C to 200°C ±1.5°C ±2.5°C
KCA
(WX)
100 Bal 43 Mn 2 – Fe 2 0°C to 150°C ±2.5°C
KCB (VX) 100 Bal 44 0°C to 100°C ±2.5°C
NX 84.4 14.2 Si 1.4 95.6 Si4.4 0°C to 200°C ±1.1°C ±2.2°C -25°C to 200°C ±1.5°C ±2.5°C
J 100 Bal 44 Mn+ 0°C to 200°C ±1.1°C ±2.2°C -25°C to 200°C ±1.5°C ±2.5°C
T 100 Bal 44 Mn+ 0°C to 100°C ±0.5°C ±1°C -25°C to 200°C ±0.5°C ±1°C
E 90 10 Bal 44 Mn+ 0°C to 200°C ±1°C ±1.7°C -25°C to 200°C ±1.5°C ±2.5°C
RCB/SCB 100 2 95 Mn+ 0°C to 100°C -25°C to 200°C ±2.5°C
Hubungi Kami